  • Lumen:
    160lm
  • Wattage:
    4 Watt
  • Lithonia
Available in increments of 1
Ordering more than 10? Request a quote and we’ll back to you with our lowest price.
More Information
Type of Area Large Retail & Open Areas, Office & Small Retail, Stairwell
Certifications NEC, NFPA, OSHA, UL Listed
Dimmable No
Lamp Life: 100,000 Hours
Number of Lamps 2 Lamp
CRI 75
Dimensions 19.25" x 8.00"
Width 19.25"
Height 8.00"
Lumen Output: 160
Manufacturer Lithonia Lighting
Product Warranty 5 year limited warranty
Part Number LHQM-LED Series
Technology LED
Voltage Multivolt 120V-277V
Wattage 4 Watt
Weight Each 3.60 lbs
Bulbs Included? Yes

ShineRetrofits Input:
Lithonia's LHQM Series is one of the most reliable and top-performing units providing both exit and emergency lighting ideal for above-the-door applications in commercial settings.  Features a rugged housing both impact and corrosion-resistant with engineering-grade thermoplastic housing and snap-together design allowing for installation in just 3 minutes!  Ensure the safety of your facility with Lithonia's LHQM emergency combo while also lowering operating costs and maintenance with a life of 100,000 hours on the exit LED lamp. 

Intended Use:
Suitable for applications requiring both exit signs and unit equipment. The attractive, 8" tall, streamlined design is great for above-the-door applications and other tight fits. An optional high-output version with remote lamps is ideal for emergency egress lighting. Certain airborne contaminants can diminish the integrity of acrylic.

Construction:
• Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant and corrosion-proof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and man-made light sources.
• Rugged unibody housing snaps together with no additional fasteners. The faceplate and back cover are interchangeable on housing. Positive snap-fit tabs hold faceplate securely, yet are easily removable for lamp compartment access. Universal, directional chevron inserts are easily removed and reinserted.
• Uniform graphics illumination without shadows or hot spots. Letters are 6" high with 3/4" stroke, with 100 ft. viewing distance rating based upon UL924 standard.
• LEDs mounted on primary circuit boards for sign illumination. Low-energy LED lamp in the exit sign operates in normal (AC input) and emergency (DC input) modes.
• Low-profile, integrated test switch/pilot light. Easily viewed bright red status indicator.
• Unique track-and-swivel arrangement permits a full range of directions of lamp head adjustment. Universal J-box mounting pattern. Toolless access for maintenance. Conduit entry position on top of unit.
• U.S. Patent No. 6,848,798; 6,499,866; 6,142,648; 5,797,673; D379,373; 5,526,251; D484,272; D473,672; 5,611,163; 5,646,502.

Optics:  
• Twin LED lamp heads operate in emergency (DC input) mode with 12 series-parallel white LEDs in each head. Provides redundant light sources to ensure emergency lighting performance. The typical life of the exit LED lamp is 10 years.

Electrical:
• Dual-voltage input capability (120/277V). The edge connector on the printed circuit board ensures long-term durability. Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs.
• Short-circuit protection — current-limiting charger circuitry protects the printed circuit board from shorts.
• Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature.
• Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/ undercharging that shortens battery life and reduces capacity.
• Filtered charger input minimizes charge voltage ripple and extends battery life.
• AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge.
• Single multi-color LED indicator to display two-state charging, test activation, and three-state diagnostic test. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for 30 seconds every 30 days, 30 minutes at 180-day intervals, and 90 minutes annually. Diagnostic evaluation of LED light source, AC-to-DC transfer, charging, and battery condition.
• Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minute capacity to emergency lamps. Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery.

Installation:
• Top, end, or back mounting. Housing snaps to canopy with positive-locking tabs. The Cam locking pin secures the housing to the canopy.
• Easily removed mounting knockouts. Conduit entry knockout for 1/2" flexible conduit. J-box pattern on the back panel.

Listings:
• UL damp location listed standard 50°-104°F (10°-40°C). Meets UL 924, NFPA 101 (current Life Safety Code), NEC, and OSHA illumination standards.

Warranty:
5-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx

Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications are subject to change without notice.

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
  • 5 Year Warranty
  • UL Listed
© 2022 ShineRetrofits.com. All Rights Reserved. Your source for induction lights, LED, and fluorescent fixtures and retrofit kits.